Cracking and ultimate shear stresses of confined masonry walls sheared horizontally


openaccess, Vol. 561 (5) 2019 / czwartek, 30 maja, 2019

(Open Access)

R. Jasiński,
T. Gąsiorowski

DOI: 10.15199/33.2019.05.06

Volume 561: Issue 5
Pages 38-39
Accepted for publication:  23.04.2019 r.

The paper presents the results of cracking and ultimate shear stresses of 6 confined walls made of AAC masonry units. The external dimensions of the walls were: thickness t = 0.18 m; length l = 4.43 m; height h = 2.49 m. The walls were tested at initial compressive stresses equal to σc = 0.1; 0.75 and 1.0 N/mm2. The values of cracking and ultimate shear stresses were analyzed in relation to the results of tests of unreinforced walls, walls reinforced with steel trusses and plastic grid. Keywords: AAC; shear walls; confined walls; cracking shear stress; ultimate shear stress.
  1. Jasiński Radosław, Tomasz Gąsiorowski. 2019. „Morfologia zarysowań ścian skrępowanych ścinanych poziomo”. Materiały Budowlane 560 (4): 23 ÷ 25. DOI: 10.15199/33.2019.04.03.
  2. Jasiński Radosław. 2018. „Size effect of monotonically sheared masonry walls made of AACmasonry units”. ICAAC6th Internationa Conference on Auto claved Aerated Concrete. Postdam, p. E12 ÷ E25. DOI: 10.1002/cepa.900.
  3. Jasiński Radosław. 2019. „Research of Influence of the Shape of Unreinforced Masonry ShearWalls Made of Calcium Silicate Masonry Units”. IOPConf. Series: Materials Science and Engineering 471 022009. DOI: 10.1088/1757-899X/471/2/022009.
  4. Jasiński Radosław. 2017. „Badania wpływu kształtu ścian murowanych z elementów silikatowych poddanych ścinaniu”. Materiały Budowlane 536 (4): 21 ÷ 26. DOI: 10.15199/33.2017.04.05.
dr hab. inż. Radosław Jasiński, prof. PS, Politechnika Śląska;Wydział Budownictwa ORCID: 0000-0003-4015-4971 mgr inż. Tomasz Gąsiorowski, Politechnika Śląska; Wydział Budownictwa

dr hab. inż. Radosław Jasiński, prof. PS, Politechnika Śląska; Wydział Budownictwa

radoslaw.jasinski@polsl.pl