How to avoid mistakes in assessment and verification of constancy of performance for sandwich panels


openaccess, Vol. 582 (2) 2021 / sobota, 20 lutego, 2021

(Open Access)

Zapolski Piotr. 2021. How to avoid mistakes in assessment and verification of constancy of performance for sandwich panels. Volume 582. Issue 2. Pages 2-4. DOI: 10.15199/33.2021.02.01

The article presents information on the selection of an appropriate system of assessment and verification of constancy of performance for self-supporting double skin metal faced insulation panels compliant fromPN-EN 14509: 2013-12. Depending of the system, the manufacturer’s scope of responsibility and the tasks of the notified body are described and potential problems with the decision to choose between system 3 and 1 for fire reaction class A, B, C. Assessment systems for sandwich panels for structural application compliant form the draft of standard EN 14509-2 are also discussed.
mgr inż. Piotr Zapolski, Sieć Badawcza Łukasiewicz – Instytut Ceramiki i Materiałów Budowlanych

mgr inż. Piotr Zapolski, Sieć Badawcza Łukasiewicz – Instytut Ceramiki i Materiałów Budowlanych

p.zapolski@icimb.pl