For shallow foundations, Eurocode EC7‒1 ignores the strength of the soil above the founding level thus causes an underestimation of the bearing capacity of the subsoil. Numerical FEM‑simulations were performed, both for constant (Dmax = Dmin = D) and for varied foundation depths on both sides of the strip foundation (Dmax>Dmin). It was found that the dominant role is played by the width of the foundation B (especially for B = 0.5 ÷ 1.0 m and for the depth D/B>3) as well as adhesion on the embedded foundation walls. The estimated implicit reserves in bearing capacity can be as great as 30÷70% for a non‑cohesive soil and even still greater for a cohesive soil. The situation is not so evident if the value (Dmax – Dmin)/B equals 3÷4 or more.

W przypadku fundamentów bezpośrednich Eurokod EC7‒1 pomija wytrzymałość gruntu powyżej poziomu posadowienia, co prowadzi do niedoszacowania nośności podłoża. Dokonano symulacji numerycznych MES, zarówno przy stałej (Dmax = Dmin = D), jak i zróżnicowanej głębokości posadowienia po obu stronach ławy (Dmax>Dmin). Stwierdzono, że dominującą rolę odgrywa szerokość ławy B (szczególnie, gdy B = 0,5 ÷ 1,0 m i zagłębienie D/B>3) oraz adhezja na zagłębionych ścianach fundamentowych. Oszacowane niejawne zapasy nośności mogą wynosić nawet 30÷70% w przypadku gruntu niespoistego i jeszcze więcej w przypadku gruntu spoistego. Sytuacja jest mniej oczywista przy wartości (Dmax – Dmin)/B równej 3÷4 i większej.
subsoil; elasto‑plasticity; FEM; strip foundation.

podłoże gruntowe; sprężysto‑plastyczność; MES; ława fundamentowa.
  1. PN‑EN 1997‒1: Eurokod 7. Projektowanie geotechniczne. Część 1: Zasady ogólne.
  2. Rybak C, Konderla P. Interférence de semelles filantes dans le domain plastique. Rev Franç Géotech, 1993;64:5‒9.
  3. Pantelidis L. Bearing capacity of shallow foundations: a focus on the depth factors in combination with the respective N‑factors. Arabian Journal of Geosciences. 2024; https://doi.org/10.1007/s12517‒024‒11976‒7.
  4. Giroud J‑P, Nhiêm T‑V, Obin, J‑P. Tables pour le calcul des fondations. Tome 3: Force portant, 1973. Paris‑Bruxelles‑Montréal: Dunod.
  5. Zadroga B., Malesiński K. Stateczność fundamentów bezpośrednich. Badania modelowe i analizy numeryczne. Gdańsk: Wydawnictwo Politechniki Gdańskiej; 2010.
  6. Salgado R, Lyamin AV, Sloan SW, Yu HS. Two‑ and three‑dimensional bearing capacity of foundations in clay. Géotechnique. 2004; https://doi. org/10.1680/geot.2004.54.5.297.
  7. Lyamin AV, Salgado R, Sloan SW, Prezzi M. Two‑and three‑dimensional bearing capacity of footings in sand. Géotechnique. 2007; https://doi. org/10.1680/geot.2007.57.8.647.
  8. Nguyen VQ, Merifield RS. Two‑and three‑dimensional undrained bearing capacity of embedded footings, 2012; Aust. Geomech. J. 42:2.
  9. PLAXIS® v.7.2. User’s Manual.
dr hab. inż. Włodzimierz Brząkała, Politechnika Wrocławska, Wydział Budownictwa Lądowego i Wodnego
ORCID 0000-0001-5535-9414
dr hab. inż. Aneta Herbut, Politechnika Wrocławska, Wydział Budownictwa Lądowego i Wodnego
ORCID 0000-0001-7106-9652

dr hab. inż. Aneta Herbut, Politechnika Wrocławska, Wydział Budownictwa Lądowego i Wodnego
ORCID 0000-0001-7106-9652

Correspondence address: aneta.herbut@pwr.edu.pl

Full paper:

DOI: 10.15199/33.2025.09.02

Article in PDF file

Received: 24.03.2025 / Artykuł wpłynął do redakcji: 24.03.2025 r.
Revised: 12.05.2025 / Otrzymano poprawiony po recenzjach: 12.05.2025 r.
Published: 19.09.2025 / Opublikowano: 19.09.2025 r.