Tests of the wall with a window zone single-story structure with confined walls subjected to vertical loads


openaccess, Vol. 647 (07) 2026 / środa, 22 lipca, 2026

Badania strefy ściany z oknem jednokondygnacyjnego obiektu ze ścianami skrępowanymi poddanego obciążeniom pionowym

(Open Access)

DOI: 10.15199/33.2026.07.01

citation/cytuj: Drobiec Ł., Mazur W., Drobiec J. Tests of the wall with a window zone single-story structure with confined walls subjected to vertical loads. Materiały Budowlane. 2026. Volume 647. Issue 07. Pages 1-6. DOI: 10.15199/33.2026.07.01

This article describes the results of tests on a spatial masonry structure with a prestressed floor. The walls of the test model were constructed fromautoclaved aerated concrete (AAC) blocks using thin-joint and without filling the vertical joints. The model walls were restrained with vertical cores and horizontal tie beams.Aunidirectionally acting prestressed composite floor was used. The model was tested under vertical loading in two stages. Stage I involved testing half of the model, including the wall with a window opening, and stage II involved testing the remaining part of the model, including the full wall. The article describes the test technique and tests results of Stage I.

W artykule opisano wyniki badań murowanego przestrzennego obiektu ze stropem sprężonym. Ściany modelu badawczego wzniesiono z bloczków z autoklawizowanego betonu komórkowego (ABK) na cienkiej spoinie i bezwypełniania spoin pionowych oraz skrępowano je pionowymi rdzeniami i poziomymi wieńcami. Zastosowano jednokierunkowo pracujący sprężony strop zespolony. Model badano pod obciążeniem pionowym w dwóch etapach. Etap pierwszy obejmował badania połowy modelu wraz ze ścianą z otworem okiennym, a etap drugi badania pozostałej części modelu wraz ze ścianą pełną. W artykule opisano technikę i wyniki badań etapu I.
autoclaved aerated concrete (AAC); confined walls; compressed walls; full-scale tests; eccentric loading.

autoklawizowany beton komórkowy (ABK); mury skrępowane; mury ściskane; badania w skali naturalnej; obciążenie mimośrodowe.
  1. PN-EN 1052-1:2000 Metody badań murów. Określenie wytrzymałości na ściskanie.
  2. PN-EN 1052-2:2016-06 Metody badań murów. Część 2: Określenie wytrzymałości na zginanie.
  3. PN-EN 1052-3:2004 Metody badań murów. Część 3: Określenie początkowej wytrzymałości muru na ścinanie. B
  4. PN-EN 1052-4:2002 Metody badań murów. Część 4: Określenie wytrzymałości na ścinanie muru z warstwą izolacji przeciwwodnej.
  5. PN-EN 1052-5: 2005Metody badań murów. Część 5: Określenie wytrzymałości na rozciąganie przy zginaniu metodą skręcania w płaszczyźnie prostopadłej do płaszczyzny muru i przy zniszczeniu rysą w spoinie wspornej.
  6. Chen D, Ma L, Wu H. Influence of boundary conditions on quasi-static out-of-plane behaviors of brick masonry infill walls: Full-scale test and numerical simulation. Engineering Structures. 2025; Volume 339, 120650.
  7. Li T, DengM, ZhangY. Effect of eccentricity on strengthening efficiency of bar mesh high ductile concrete (BMHDC) on slender masonry columns. Engineering Structures. 2021; Volume 230,111732.
  8. Galman I, Jasiński R. Procedura i badania weryfikacyjne wyznaczania wytrzymałości na ścinanie połączeń ścian murowanych. Materiały Budowlane. 2026 (1): 91 – 92.
  9. Drobiec Ł. Study of impact of bed joint reinforcement on load-carrying capacity and crack resistance of masonry walls made of calcium silicate units. Journal of Building Engineering. 2021, 101841.
  10. Drobiec Ł, Mazur W, Rybarczyk T. Analysis of confined AAC walls under monotonic compression. Engineering Structures. 2022; Volume 253, 113756.
  11. Piekarczyk A. Badania ścian zbrojonych i niezbrojonych z bloczków z ABK podpartych na uginającej się konstrukcji. Materiały Budowlane. 2020 (4): 28 – 33.
  12. Hung C-C,Wang Y-Q, Yen C-H. Retrofitting of masonry-infilled RC frames using UHPC shotcrete: Full-scale experiments and strength modelling. Construction and Building Materials. 2026; Volume 537, 146982.
  13. Grzyb K, Jasiński R. Stiffness of unreinforced masonry shear walls based on full-scale testing. Journal of Building Engineering. Volume 120, 115597.
  14. Grzyb K, HuaY, Jasiński R. Redistribution of internal forces inmasonry walls: a study through full-scale experiments and numerical simulations. Engineering Structures. 2025; Volume 340, 120758.
  15. Drobiec Ł, Drobiec J. Zbrojenie spoin wspornych przy otworach ścian z ABK. Materiały Budowlane. 2026 (4): 75 – 76.
prof. dr hab. inż. Łukasz Drobiec, Politechnika Śląska; Wydział Budownictwa
ORCID: 0000-0001-9825-6343
dr inż. Wojciech Mazur, Politechnika Śląska; Wydział Budownictwa
ORCID: 0000-0001-6382-1496
dr inż. Joanna Drobiec, Uniwersytet Zielonogórski; Instytut Budownictwa
ORCID: 0009-0000-4364-8841

prof. dr hab. inż. Łukasz Drobiec, Politechnika Śląska; Wydział Budownictwa
ORCID: 0000-0001-9825-6343

Correspondence address: lukasz.drobiec@polsl.pl

Full paper:

DOI: 10.15199/33.2026.07.01

Article in PDF file

Received: 06.03.2026 / Artykuł wpłynął do redakcji: 06.03.2026 r.
Revised: 27.04.2026 / Otrzymano poprawiony po recenzjach: 27.04.2026 r.
Published: 22.07.2026 / Opublikowano: 22.07.2026 r.