(Open Access)
R. Jasiński,
T. Gąsiorowski
Volume 560: Issue 4
Pages 23-25
Accepted for publication: 05.03.2019 r.
The paper presents the results of confined (6 walls) made of masonry elements with AAC. Overall dimensions were: thickness t = 0.18 m, length l = 4.43 m and the height of h = 2.43 m. The walls were tested at initial compressive stresses perpendicular to the plane of the bed joints σc = 0,1; 0,75; and 1,0 N/mm2. In the confinedmodels two external vertical cores and two horizontal beams were made, which were reinforced in accordance with the requirements of PN-EN-1996-1-1. The morphology of cracking and the mechanism of destruction were analyzed.
Keywords: AAC; shear walls; confined walls; cracks patterns; failure mechanism.
- AsinariM. 2007. Buildingswith structuralmasonry walls connected to tie-columns and bond-beams. Praca doktorska, Università degli Studi di Pavia.
- ASTM E519-81 Standard Test Method for Diagonal Tension (Shear) of Masonry Assemblages.
- Brzev S. 2007. Earthquake-Resistant Confined Masonry Construction. National Information Center of Earthquake Engineering Indian Institute of Technology Kanpur, India.
- Jasiński Radosław. 2018. Size effect of monotonically sheared masonry walls made of AAC masonry units. ICAAC 6th International Conference onAutoclavedAerated Concrete. Postdam, september 4-6 r. str. E12 ÷ E25. DOI. org/10.1002/cepa.900.
- Jasiński Radosław. 2019. „Research of Influence of the Shape of Unreinforced Masonry Shear Walls Made ofCalciumSilicateMasonryUnits”. IOPConf. Series: Materials Science and Engineering 471 022009. DOI: 10.1088/1757-899X/471/2/022009.
- Jasiński Radosław. 2017. „Badania wpływu kształtu ścian murowanych z elementów silikatowych poddanych ścinaniu”. Materiały Budowlane 536 (4): 21÷26. DOI: 10.15199/33.2017.04.05.
- PN-EN 1996-1-1+A1:2013-05P Projektowanie konstrukcji murowych. Część 1-1. Reguły ogólne dla zbrojonych i niezbrojonych konstrukcji murowych.
- PN-EN 1052-1:2000: Metody badań murów. Określenie wytrzymałości na ściskanie.
- PN-EN 1052-3:2004 Metody badań murów. Część 3: Określanie początkowej wytrzymałości muru na ścinanie.
- Tena-ColungaA.,A. Juárez-Ángeles,V. H. Salinas-Vallejo. 2009. „Cyclic behavior of combined and confinedmasonry walls”. Engineering Structures, vol. 31: 240 – 259.
- Timperman P., J. A. Rice. 1995. Bed joint reinforcement in masonry. Proceedings of the Fourth International Masonry Conference. BritishMasonry Society. London, vol. 2: 451 – 453.
- Torrisi G. S., F. J. Crisafulli, A. Pavese. 2012. An innovative Model for the In-Plane Nonlinear Analysis of Confined Masonry and Infilled Frame Structures. Proceedings of the 15th World Conference on Earthquake Engineering, Lizbona.
dr hab. inż. Radosław Jasiński, prof. PŚ, Politechnika Śląska;Wydział Budownictwa
mgr inż. Tomasz Gąsiorowski, Politechnika Śląska;Wydział Budownictwa
dr hab. inż. Radosław Jasiński, Politechnika Śląska; Wydział Budownictwa
Full paper: