(Open Access)
Z. Matkowski,
A. Klimek
Volume 561: Issue 5
Pages 8-10
Accepted for publication: 10.04.2019 r.
In order to protect surfaces of vertical external walls from moisture penetration sideways, the so-called wall ventilation galleries were very often used in the past. The main function of those elements was to make it possible for moisture to evaporate through external surfaces, which contributed to reducing moisture level and moisture rising by capillary action. The ventilation galleries functioned well provided there was adequate air-circulation around the protected walls and proper drainage of rainwater from the bottom. At present, while designing building renovation, wall ventilation galleries are liquidated and backfilled. If there are faults in the design and application of insulation, backfilling the gallery may bring adverse effects.
- Hoła Jerzy, Zygmunt Matkowski. 2009. „Awarie budowlane: zapobieganie, diagnostyka, naprawy, rekonstrukcje”. XXIV Konferencja naukowo- techniczna, Szczecin-Międzyzdroje.Wydawnictwo Uczelniane Zachodniopomorskiego Uniwersytetu Technologicznego: 73.
- Hoła Jerzy, Jan Sikora i inni. 2010. New Tomographic method of brickwork damp identification. Wrocław. Oficyna Wydawnicza Politechniki Wrocławskiej.
- Matkowski Zygmunt. 2002. „Problems involved in nondestructive investigations of brick walls (in Polish)”. Proc. of 31st Domestic Conference on Nondestructive Tests, 31 KKBN, Szczyrk, 22-24 X 2002, Zeszyty Problemowe Badania Nieniszczące (7): 131 – 134.
- Praca zbiorowa pod redakcją Jerzego Karysia. 2014. Ochrona budynków przed wilgocią i korozją biologiczną w budownictwie. Rozdział 12. Warszwa. Grupa Medium.
- Rokiel Maciej. 2009. Hydroizolacje w budownictwie. Warszawa. Grupa Medium.
dr inż. Zygmunt Matkowski, dr inż. Adam Klimek, Politechnika Wrocławska; Wydział Budownictwa Lądowego i Wodnego
dr inż. Zygmunt Matkowski, Politechnika Wrocławska; Wydział Budownictwa Lądowego i Wodnego zygmunt.matkowski@pwr.wroc.pl
Full paper: