Section models for analysis of the resistance of masonry tower structures


Vol. 554 (10) 2018 / czwartek, 1 listopada, 2018

(InPolish)

M. Lechman

DOI: 10.15199/33.2018.10.40

Volume 554: Issue 10
Pages 129-130
Accepted for publication: 07.09.2018 r.

The paper presents sectionmodels for of the resistance ofmasonry tower structures.Assuming the nonlinear stress-strain relationship for masonry in compression taking into account the effect of its softening.The cross-sectional resistances nmu are derived mmu in the analytical form by integrating the equilibrium equations and taking into account the geometrical and physical relationship. The calculated results are presented in the form of interaction diagrams nmu – mmu and compared with those based on the parabolic-rectangular diagramformasonry in compression. Keywords: sectionmodels; resistance;masonry tower structures.
  1. Lechman Marek. 2006. Nośność i wymiarowanie przekrojów pierścieniowych elementów mimośrodowo ściskanych”.Warszawa, Prace Naukowe Instytutu Techniki Budowlanej, Rozprawy,Wydawnictwa Instytutu Techniki Budowlanej.
  2. Nieser Horst, Viktor Engel. 1986. Industrieschornsteine in Massivbau, Beuth, Berlin.
  3. PN-EN 1992-1-1:2008 Eurokod 2. Projektowanie konstrukcji z betonu. Część 1-1: Reguły ogólne i reguły dla budynków.
  4. PN-EN 1996-1-1:2005+A1:2012 Eurokod 6. Projektowanie konstrukcji murowych. Część 1-1: Reguły ogólne dla zbrojonych i niezbrojonych konstrukcji murowych.
dr hab. inż. Marek Lechman, prof. nadzw. ITB, Instytut Techniki Budowlanej; Zakład Konstrukcji Budowlanych, Geotechniki i Betonu;

dr hab. inż. Marek Lechman

 m.lechman@itb.pl

Full paper is available at Publisher house SIGMA-NOT Sp. z o.o. webpage

DOI: 10.15199/33.2018.10.40