The paper presents the results of tests of 9 reinforced masonry walls made of autoclaved aerated concrete (AAC). The modelswere reinforcedwith truss type steel reinforcement orwith plastic grids. The influence of reinforcement cover on the wall parameters was analysed. In 6models, a so-called one-sided bed joints was used (reinforcement was embedded in the mortar), and the next in 3 models a two-sided bed joints was used (reinforcement was laid on the mortar joint and covered with another layer of mortar). The models were tested under compression in accordancewith PN-EN1052-1:2000. The results were compared with the results of tests of unreinforced walls.
Keywords: execution of masonry structures; bed joint reinforcement; compression.
Keywords: execution of masonry structures; bed joint reinforcement; compression.
- ASTMD 6637 Standard Test Method for Determining Tensile Properties of Geogrids by the Single or Multi-Rib Tensile Method.
- Drobiec Łukasz, Radosław Jasiński. 2015. „Wpływ rodzaju zaprawy na parametry mechaniczne murów z ABK poddanych ściskaniu”. Materiały Budowlane 512 (4): 3 – 7. DOI: 10.15199/33.2015.04.02.
- Drobiec Łukasz, Radosław Jasiński. 2015. „Wpływ rodzaju zaprawy na parametry mechaniczne murów z betonu komórkowego poddanych ścinaniu”. Materiały Budowlane 513 (5): 106 – 109. DOI: 10.15199/33.2015.05.44.
- Drobiec Łukasz, Radosław Jasiński, Tomasz Rybarczyk. 2016. „The influence of the type of mortar on the compressive behaviour of walls made of Autoclaved Aerated Concrete (AAC)”. Brick and Block Masonry – Trends, Innovations and Challenges. London. Taylor & Francis Group: 1531–1538.
- Jasiński Radosław, Łukasz Drobiec. 2016. „Comparison Research of Bed Joints Construction and Bed Joints Reinforcement on Shear Parameters of AAC Masonry Walls”. Journal of Civil Engineering and Architecture, Vol. 10 (12): 1329 – 1343.DOI: 10.17265/1934-7359/2016.12.004.
- Jasiński Radosław, Łukasz Drobiec. 2016. „Study of Autoclaved Aerated Concrete Masonry Walls with Horizontal Reinforcement under Compression and Shear”. Procedia Engineering, vol. 161: 918 – 924. DOI: 10.1016/j.proeng.2016.08.758.
- PN-EN 1052-1:2000 Metody badań murów. Część 1. Określenie wytrzymałości na ściskanie.
- PN-EN 1996-1-1:2010+A1:2013-05P, Eurocode 6: Projektowanie konstrukcji murowych. Część 1-1: Reguły ogólne dla niezbrojonych i zbrojonych konstrukcji murowych.
- dr inż. Radosław Jasiński Politechnika Śląska,Wydział Budownictwa
- dr hab. inż. Łukasz Drobiec, prof. Politechnika Śląska,Wydział Budownictwa
dr inż. Radosław Jasiński