(in Polish)
P. Górski,
T. Chmielewski
Volume 525; Issue 5
Pages 34-35
Accepted for publication: 21.03.2016 r.
This paper deals with the selection of parameters for filtering of GPS signals for the detection of the displacements of the 300 m tall chimney in order to limit the influence of the background noise of GPS technology. After filtering of the signals the significant improvement of dynamic deformationsmonitoring accuracy is obtained.
Keywords: Industrial chimney, GPS, displacements, filtration.
Keywords: Industrial chimney, GPS, displacements, filtration.
- Casciati Fabio, Clemente Fuggini. 2009. „Engineering vibration monitoring by GPS: long duration records”. Earthquake Engineering and Engineering Vibration 8 (3): 459–467. DOI: 10.1007/s11803-009-9058-8
- Psimoulis Panos, Stella Pytharouli, Dimitris Karambalis, Stathis Stiros. 2008. „Potential of Global Positioning System (GPS) to measure frequencies of oscillations of engineering structures”. Journal of Sound and Vibration 318: 606–623. DOI: 10.1016/j.jsv.2008.04.036.
- Breuer Peter, Tadeusz Chmielewski, Piotr Górski, Eduard Konopka, Lesław Tarczyński. 2015. „Monitoring horizontal displacements in a vertical profile of a tall industrial chimney using Global Positioning System technology for detecting dynamic characteristics”. Structural Control and Health Monitoring 22 (7): 1002-1023. DOI: 10.1002/stc.1730.
Piotr Górski, Ph. D. Eng. - Opole University of Technology, Faculty of Civil Engineering and Architecture
Tadeusz Chmielewski, Prof. - Opole University of Technology, Faculty of Civil Engineering and Architecture
Tadeusz Chmielewski, Prof. - Opole University of Technology, Faculty of Civil Engineering and Architecture
Piotr Górski, Ph. D. Eng.
Full paper is available at Publisher house SIGMA-NOT Sp. z o.o. webpage