The problem of noise generated during the use of garage parking platforms in residential buildings


openaccess, Vol. 626 (10) 2024 / piątek, 25 października, 2024

Problem hałasu generowanego podczas użytkowania garażowych platform parkingowych w budynkach mieszkalnych

(Open Access)

DOI: 10.15199/33.2024.10.03

citation/cytuj: Szeląg A., Kłosak A., Ziarko B. The problem of noise generated during the use of garage parking platforms in residential buildings. Materiały Budowlane. 2024. Volume 626. Issue 10. Pages 17-28. DOI: 10.15199/33.2024.10.03

In this article, an analysis of the noise problem generated during the use of parking platforms located in the underground garage of a multi-family residential building is presented. Based on in-situ studies, it has been shown how significant the exceedance of permissible sound levels can be in protected rooms during the operation of improperly acoustically secured parking platforms. Repeat measurements taken after implementing of noise protection demonstrated that the potential to solve the issue of noise transmission from the platforms to residential units after their installation is very limited and ineffective if the building's structural design did not consider appropriate protections at design stage. The article discusses measurement procedures, obtained results, and the extent to which standards were exceeded, and proposes possible construction and structural solutions that should reduce the risk of parking platform noise being audible in acoustically protected rooms, such as living spaces.

W artykule przedstawiono analizę problemu hałasu generowanego podczas użytkowania platform parkingowych zlokalizowanych w garażu podziemnym wielorodzinnego budynku mieszkalnego. Na podstawie badań in situ wykazano, jak duże przekroczenie dopuszczalnych poziomów dźwięku może występować w pomieszczeniach chronionych podczas eksploatacji nieodpowiednio zabezpieczonych akustycznie platform parkingowych. Wykonując powtórne pomiary po wprowadzeniu zabezpieczeń, wykazano, że możliwości rozwiązania problemu transmisji hałasu od platform do lokali mieszkalnych już po montażu platform są bardzo ograniczone i mało skuteczne, jeśli projekt konstrukcyjny budynku nie uwzględniał odpowiednich zabezpieczeń. W artykule omówiono procedury pomiarowe, uzyskane wyniki i skalę przekroczenia wymagań normowych oraz zaproponowano możliwe rozwiązania konstrukcyjno-budowlane, które powinny ograniczyć ryzyko słyszalności platform parkingowych w pomieszczeniach chronionych akustycznie, takich jak pomieszczenia mieszkalne.
parking platforms; noise from technical equipment; structure-borne noise; housing.

platformy parkingowe; hałas od wyposażenia technicznego; dźwięki materiałowe; zabudowa mieszkaniowa.
  1. Wieteska-Rosiak B. Problematyka lokalizacji parkingów wielopoziomowych na osiedlach mieszkaniowych z wielkiej płyty. Transport Miejski i Regionalny. 2012; 7: 28 – 32.
  2. Szumilas AK, Pach PA. Review of parking policies in the case ofmediumsized Polish cities. Procedia Engineering. 2017; 192: 863 – 868.
  3. Ilmurzyńska K. Parkowanie na wielkich osiedlach mieszkaniowych a zrównoważona polityka parkingowa, Builder, PWBMEDIA. 2024; 2, 2 – 5 [Builder Science], DOI: 10.5604/01.3001.0054.2816.
  4. Rozporządzenie Ministra Infrastruktury z 12 kwietnia 2002 r. w sprawie warunków technicznych, jakim powinny odpowiadać budynki i ich usytuowanie, Dz. U. 2002 nr 75 poz. 690 z późniejszymi zmianami.
  5. Rakoczy P. Automatyczne systemy parkingowe – gdzie i dla kogo? Autostrady. 2016; 8-9: 64 – 65.
  6.  Guangmei W, Xianhao X, Yeming (Yale) Gong, Ren«e De Koster, Bipan Z. Optimal Design and Planning for Compact Automated Parking Systems, European Journal ofOperational Research. 2018; doi: https://doi.org/10.1016/ j.ejor.2018.09.014.
  7.  Zhou Xuhong, Zhang Jingshu, NieHuanhuan, Wang Haicui, Li Jiang, „The key problems in the design of lift-sliding mechanical parking system”, International Conference onMechanicAutomation and Control Engineering MechanicAutomation and Control Engineering (MACE), 2010 International Conference on. 4983-4987 Jun, 2010.
  8. PN-B-02151-02:1987 Akustyka budowlana. Ochrona przed hałasem pomieszczeń w budynkach. Dopuszczalne wartości poziomu dźwięku w pomieszczeniach.
  9.  PN-B 02151-2:2018-01 Akustyka budowlana – Ochrona przed hałasem w budynkach – Część 2: Wymagania dotyczące dopuszczalnego poziomu dźwięku w pomieszczeniach. PKN 2018.
  10.  PN-EN ISO 140-4: 2000 Akustyka. Pomiar izolacyjności akustycznej w budynkach i izolacyjności akustycznej elementów budowlanych. Pomiary terenowe izolacyjności od dźwięków powietrznych między pomieszczeniami.
  11. PN-B-02156:1987 Akustyka budowlana. Metody pomiaru poziomu dźwięku A w budynkach.
  12.  PN-EN ISO 717-1:2013-08Akustyka. Ocena izolacyjności akustycznej w budynkach i izolacyjności akustycznej elementów budowlanych. Część 1: Izolacyjność od dźwięków powietrznych.
  13.  PN-B-02151-3:2015-10Akustyka budowlana – Ochrona przed hałasem w budynkach – Część 3: Wymagania dotyczące izolacyjności akustycznej przegród w budynkach i elementów budowlanych.
  14. Casini M (Editor). In Woodhead Publishing Series in Civil and Structural Engineering, Construction 4.0. Woodhead Publishing, 2022, ISBN 9780128217979, https://doi. org/10.1016/B978-0-12-821797- 9.00016-7.
  15.  PN-EN ISO 12999-1:2021-05 Akustyka – Wyznaczanie i stosowanie niepewności pomiarów w akustyce budowlanej – Część 1: Izolacyjność akustyczna, PKN.
dr inż. Agata Szeląg, Politechnika Krakowska
ORCID: 0000-0002-9058-565X
dr hab. inż. arch. Andrzej Kłosak, prof. PK, Politechnika Krakowska
ORCID: 0000-0001-6326-1652
mgr inż. arch. Bartłomiej Ziarko, Politechnika Krakowska
ORCID: 0000-0002-8836-5586

dr inż. Agata Szeląg, Politechnika Krakowska
ORCID: 0000-0002-9058-565X

Correspondence address: agata.szelag@pk.edu.pl

Full paper:

DOI: 10.15199/33.2024.10.03

Article in PDF file

Received: 09.07.2024 / Artykuł wpłynął do redakcji: 09.07.2024 r.
Revised: 06.09.2024 / Otrzymano poprawiony po recenzjach: 06.09.2024 r.
Published: 22.10.2024 / Opublikowano: 22.10.2024 r.