In the paper the repair ofmore than 400 natural draught cooling towers columns in one of the Polish power stations in years 2004 – 2013 is presented. The estimation of the quality control during the execution and assessment of the surface protection coating of the repaired columns are described.
Keywords: cooling towers, columns repairs, surface protection coating.