(Open Access)
DOI: 10.15199/33.2022.03.03
Wójcik Robert. 2022. Dehumidification of historic foundation walls using the dual-purpose drainage. Volume 595. Issue 3. Pages 20-24. Article in PDF file
Accepted for publication: 31.02.2022 r.
It is very difficult to protect historic buildings set on massive foundations against ground damp. The methods used so far are unreliable, and the taken actions often bring the opposite effects. Therefore, there is a need to search for new, more effective and minimally invasive methods of protecting structures against groundwater. The article presents the proprietary dual-purpose drainage method that is currently being implemented. The method consists on separating the filter zone (chimney) into a drying and drainage zone. It is possible thanks to the newest materials, such as waterproof and, at the same time, vapor-permeable membranes separating the drying bed.
- Klemm P. (red.). 2005. Budownictwo ogólne. Fizyka budowli..
- Szymkiewicz A., Z. Sikora, R. Osowski, W. Tisler. 2014. „Właściwości retencyjne, przewodność hydrauliczna i naprężenia efektywne w gruntach nienasyconych”. Inżynieria Morska i Geotechnika 5/2.
- Wójcik R. 2019. „Co inżynier budownictwa powinien wiedzieć o osuszaniu budynków”. Inżynier Budownictwa 4: 60 – 66.
- Wójcik R. 2010. „Porady praktyczne dla powodzian na przykładzie Wilkowa”.Materiały Budowlane 7: 89 – 92.
dr hab. inż. Robert Wójcik, prof. UWM, UniwersytetWarmińsko-Mazurski; Wydział Geoinżynierii
ORCID: 0000-0002-3142-7969
dr hab. inż. Robert Wójcik, prof. UWM, UniwersytetWarmińsko-Mazurski; Wydział Geoinżynierii ORCID: 0000-0002-3142-7969