The problem of stress concentration at the corner of composite bars


openaccess, Vol. 646 (06) 2026 / czwartek, 25 czerwca, 2026

Problem koncentracji naprężeń w narożu prętów kompozytowych

(Open Access)

DOI: 10.15199/33.2026.06.02

citation/cytuj: Szczech D. The problem of stress concentration at the corner of composite bars. Materiały Budowlane. 2026. Volume 646. Issue 06. Pages 10-16. DOI: 10.15199/33.2026.06.02

The article addresses the issue of stress concentration at the corner of composite reinforcement. Due to the weakening effect caused by the bending of the bar at the corner, there is a significant reduction in the shear strength of the reinforcement. The shear capacity of bent FRP bars is analysed in the context of design standards, and in comparison with traditional steel reinforcement.

W artykule przedstawiono problem koncentracji naprężeń w narożu zbrojenia kompozytowego. Ze względu na osłabienie zagięcia pręta w narożu następuje znaczna redukcja nośności zbrojenia na ścinanie. Przeanalizowano nośność pręta zagiętego FRP w świetle norm projektowych, a także w porównaniu z tradycyjnym zbrojeniem stalowym.
stress concentration; FRP; stirrups, bent strength.

koncentracja naprężeń; FRP; strzemiona, nośność pręta zagiętego.
  1. Eshani MR, Saadatmanesh H, Tao S. “Bond of Hooked Glass Fiber Reinorced Plastic (GFRP) Reinforcing Bars to Concrete.” Materials Journal, (1995) 122 (3), 247‒257.
  2. Maruyama K, Zhao W. “Flexural and Shear Behavior of Concrete Beams Reinforced by FRP Rods.” Inter. Conf. on Corrosion and Corrosion Protection of Steel in Concrete, Sheffield (1994) p. 1330‒1339.
  3.  Nagasaka T, Fukuyama H, Tanigaki M. “Shear performance of concrete beams reinforced with FRP stirrups.” Special publication (1993) 138 789‒812.
  4. Pilakoutas K. CIV4170/6170 FRP Composites in Construction. The University of Sheffield.
  5.  Ishihara K, Obara T, Sato Y, Ueda T, Kakuta Y. “Evaluation of Ultimate Strength of FRP Rods at Bent-up Portion.” Proceedings of the 3rd International Symposium on Non-Metallic (FRP) Reinforcement for Concrete Structures, Sapporo, Japan, (1997) 2: 27‒34.
  6.  Shehata E, Morphy R, Rizkalla S. “Fibre Reinforced Polymer Shear Reinforcement for Concrete Members: Behaviour and Design Guidelines.“ Canadian Journal of Civil Engineering, (2000) 27 p. 859‒872.
  7. Matta F, Nanni A, Galati N, Mosele F. “Size effect on shear strength of concrete beams reinforced with FRP bars. “Proc. of the 6th Inter. Conf. on FraMCoS, (2007) Vol. 2, pp. 17‒22.
  8. Szczech D, Kotynia R. “Shear tests on GFRP reinforced concrete beams.” 10th International Conference on AMCM. MATEC Web od Conf. (2020) Vol. 323.
  9. Szczech D. Rozprawa doktorska (2023) „Analiza wpływu rodzaju zbrojenia na nośność ścinania betonowych belek ze zbrojeniem poprzecznym” Politechnika Łódzka, Łódź, 2023.
  10.  Krall M, Polak MA. Concrete beams with different arrangements of GFRP flexural and shear reinforcement. Engineering Structures, 2019;198 (5): 109333.
  11. Bywalski C, Drzazga M, Kaźmierowski M, Kamiński M. “Shear Behavior of Concrete Beams Reinforced with a New Type of Glass Fiber Reinforced Polymer Reinforcement: Experimental Study.” Materials. 2020; 13 (5): 1159.
  12. Huang Z, Chen W, Hao H, Chen Z, Pham T, Tran T, Elchalakani M. “Shear behaviour of ambient cured geopolymer concrete beams reinforced with BFRP bars under static and impact loads” Engineering Structures (2021) 231: 111730
  13. Whitehead PA, Ibell TJ. “Novel shear reinforcement for fiber reinforced polymer reinforced and prestressed concrete.” ACI Structural Journal (2005) 102 (2): 286–94.
  14. Kim H, Him MS, Ko MJ, Lee YH. “Shear behavior of concrete beams reinforced with GFRP shear reinforcement.” International Journal of Polymer Science (2015) 1–8.
  15.  Ueda T, Sato Y, Kakuta Y, Imamura A, Kanematsu H. “Failure Criteria for FRP rods Subjected to a Combination of Tensile and Shear Forces.” Proc. of FRPRCS-2 (1995) p. 26–33.
  16.  ACI 440.1R-15 (2015) Guide for the Design and Construction of Structural Concrete Reinforced with FRP Bars, American Concrete Institute.
  17.  Kanematsu H, Sato Y, Ueda T, Kakuta Y. “A study on failure criteria of FRP rods subject to tensile and shear force.” Proceedings of the FIP’93 symposium – modern prestressing techniques and their applications. Tokyo: Japan Prestressed Concrete Engineering Association (1993) vol. 2., p. 743–50.
  18. Ahmed EA, El-Salakawy EF, Benmokrane B. “Performance Evaluation of Glass Fiber-Reinforced Polymer Shear Reinforcement for Concrete Beams” ACI Structural Journal (2010) 107-S06.
  19. Mochizuki S, Matsuzaki Y, Sugita M. “Evaluation Items and Methods of FRP Reinforcement as Structural Elements, ” Fiber-Reinforced- Plastic Reinforcement for Concrete Structures: International Symposium, SP-138, American Concrete Institute, Farmington Hills (1993) p. 117‒131.
  20. Ibell T, Burgoyne J. “Use of Fiber-Reinforced Plastics Versus Steel for Shear Reinforcement of Concrete, ” ACI Structural Journal. (1999) V. 96, No. 6, pp. 997‒1002.
  21. Nakamura H, Higai T. „Evaluation of shear strength of concrete beams reinforced with FRP.” Concrete Library of JSCE (1995) No. 508/V-26: 111‒123.
  22. Miyata S, Tottori S, Terada T, Sekijima K. “Experimental study on tensile strength of FRP bent bar.” Transactions of the Japan Concrete Institute (1989) 11, 185–191.
  23. CEN (2017) CEN/TC 250/SC 2/WG 1/TG 1 N 110 Draft Reinforcing With FRP.
  24. CAN/CSA-S806‒12 (2012) Design and construction of building structures with fibre-reinforced polymers, Canadian Standards Association, Ontario, Canada.
  25. JSCE (1997) Recommendation for design and construction of concrete structures using continuous fiber reinforcing materials. (Concrete Engineering Series JSCE).
  26. Bentz EC, Massam L, Collins MP. „Shear strength of large concrete members with FRP reinforcement.” Journal of Composites for Construction (2010) 14 (6), 637‒646.
  27. Yuan Y, Wang Z. (2019) “Shear behavior of large-scale concrete beams reinforced with CFRP bars and handmade strip stirrups.” Composite Structures 227.
  28.  Lee C, Kim J, Heo S. “Experimental observation on the effectiveness of fiber sheet strip stirrups in concrete beams.” Journal of Composites for Construction (2010) 14 (5): 487–97.
  29. Spadea S, Orr J, Ivanova K. “Bend-strength of novel filament wound shear reinforcement.” Composite Structures (2017) 176:244–53.
  30.  Imjai T. (2007) “Design and analysis of curved FRP composites as shear reinforcement for concrete structures.” Dissertation PhD thesis, The University of Sheffield, Dept. of Civil and Structural Engineering, Sheffield, UK.
  31.  Bright RJ, Sumathi M. (2017) “Failure Analysis of FRP Composite Laminates Using Progressive Failure Criteria.” International Journal of Scientific & Engineering Research 8.
  32. PN-EN 1992‒1-1 (2008) Eurokod 2. Projektowanie konstrukcji z betonu. Część 1‒1: Reguły ogólne i reguły dla budynków.
dr inż. Damian Szczech, Politechnika Łódzka, Wydział Budownictwa, Architektury i Inżynierii Środowiska
ORCID: 0000-0002-8357-2877

dr inż. Damian Szczech, Politechnika Łódzka, Wydział Budownictwa, Architektury i Inżynierii Środowiska
ORCID: 0000-0002-8357-2877

Correspondence address: damian.szczech@p.lodz.pl

Full paper:

DOI: 10.15199/33.2026.06.02

Article in PDF file

Received: 02.03.2026 / Artykuł wpłynął do redakcji: 02.03.2026 r.
Revised: 09.04.2026 / Otrzymano poprawiony po recenzjach: 09.04.2026 r.
Published: 24.06.2026 / Opublikowano: 24.06.2026 r.